排序方式: 共有55条查询结果,搜索用时 31 毫秒
1.
Takeshi Sasaki Atsushi Iizuka Masayuki Watanabe Teruhisa Hongo Akihiro Yamasaki 《Waste management (New York, N.Y.)》2014,34(10):1829-1835
Solid adsorbent materials, prepared from waste cement powder and concrete sludge were assessed for removal of arsenic in the form of arsenic (As(V)) from water. All the materials exhibited arsenic removal capacity when added to distilled water containing 10–700 mg/L arsenic. The arsenic removal isotherms were expressed by the Langmuir type equations, and the highest removal capacity was observed for the adsorbent prepared from concrete sludge with heat treatment at 105 °C, the maximum removal capacity being 175 mg-As(V)/g. Based on changes in arsenic and calcium ion concentrations, and solution pH, the removal mechanism for arsenic was considered to involve the precipitation of calcium arsenate, Ca3(AsO4)2. The enhanced removal of arsenic for the adsorbent prepared from concrete sludge with heat treatment was thought to reflect ion exchange by ettringite. The prepared adsorbents, derived from waste cement and concrete using simple procedures, may offer a cost effective approach for arsenic removal and clean-up of contaminated waters, especially in developing countries. 相似文献
2.
Tong Huang Motohiro Miura Shogo Nobukawa Masayuki Yamaguchi 《Journal of Polymers and the Environment》2014,22(2):183-189
Effect of the addition of poly(ethylene glycol) terminated by benzoate (PEG-BA) on the crystallization behavior and dynamic mechanical properties of poly(l-lactic acid) PLLA is studied as compared with poly(ethylene glycol) (PEG-OH). It is found that PEG-BA is miscible with PLLA and shows good plasticizing effect. Because PEG-OH having the same degree of polymerization is immiscible with PLLA, the end group in PEG-BA, i.e., benzoate, plays an important role in the miscibility. Furthermore, PEG-BA does not induce the PLLA degradation at melt-processing, whereas PEG-OH leads to the hydrolysis degradation. Finally, the addition of PEG-BA pronounces the crystallization rate of PLLA at low crystallization temperatures and thus enhances the degree of crystallinity at conventional processing. Consequently, the temperature dependence of dynamic mechanical properties are similar to that for isotactic polypropylene. 相似文献
3.
Masayuki Taniguchi Kenji Yamamoto Teruyuki Okazaki Sebastian Rehfeldt Christian Kuhr 《International Journal of Greenhouse Gas Control》2011
Previously, we developed a model to predict lean flammability limit L and flame propagation velocity Sb for pulverized coal. In the present paper, we have extended the model to apply it in development of oxy-fuel combustion systems. The basic model consists of two particles. One of the two particles burns first, then, the other particle is ignited by the heat of combustion of the one burning particle. We analyzed at what distance the first burning particle could ignite the next particle, and how fast the first burning particle could ignite the next particle. The model was verified both for air and oxy-fuel combustion conditions. Next, a method to support burner development was examined by using the model. Local Sb and L near the ignition points of the burner could be analyzed from the concentration and temperature profiles of CFD results. Flame stability was judged by the calculated Sb and L profiles, and past results of blow-off limits obtained with actual- and pilot-scale experiments. A DS®T-burner was developed by Hitachi Power Europe, and installed at the Schwarze Pumpe pilot plant. Combination of the technique and large eddy simulation was applied to confirmation of the system. 相似文献
4.
Masayuki Tanabe Atsumi Miyake 《Journal of Loss Prevention in the Process Industries》2011,24(4):383-390
The functional safety requirement is widely applied in the process plant industry in accordance with the international standards, such as IEC and ISA. The requirement is defined as safety integrity level (SIL) based on the risk reduction concept for protection layers, from original process risk to tolerable risk level. Although the standards specify both, the Prevention System and the Emergency System, as level of protection layers, the standards specify in detail only the use of the Prevention System (i.e., Safety Instrumented System (SIS)). The safety integrity level is not commonly allocated to the Emergency System (e.g., Fire and Gas System, Emergency Shutdown System and Emergency Depressuring System). This is because the required risk reduction can be normally achieved by only the Prevention System (i.e., SIS and Pressure Safety Valve (PSV)). Further, the risk reduction level for the Emergency System is very difficult to be quantified by the actual SIL application (i.e., evaluated based on the single accident scenario, such as an accident from process control deviation), since the escalation scenarios after Loss of Containment (LOC) greatly vary depending on the plant design and equipment. Consequently, there are no clear criteria for evaluating the Emergency System design. This paper aims to provide the functional safety requirement (i.e., required risk reduction level based on IEC 61508 and 61511) as design criteria for the Emergency System.In order to provide clear criteria for the Emergency System evaluation, a risk reduction concept integrated with public’s perception of acceptable risk criteria is proposed and is applied to identify the required safety integrity level for the Emergency System design. Further, to verify the safety integrity levels for the Emergency Systems, the probabilistic model of the Emergency Systems was established considering each Emergency System (e.g., Fire and Gas System, Emergency Shutdown System and Emergency Depressuring System) relation as the Overall Emergency System. This is because the Overall Emergency System can achieve its goal by the combined action of each individual system, including inherent safe design, such as separation distance.The proposed approach applicability was verified by conducting a case study using actual onshore Liquefied Natural Gas Plant data. Further, the design criteria for Emergency Systems for LNG plants are also evaluated by sensitivity analysis. 相似文献
5.
Minoru Ichihara Keisuke Maruyama Masayuki Yamashita Hitoshi Sawada Hidehiro Inagaki Yoshiki Ishida Motoaki Asai 《Agriculture, ecosystems & environment》2011,140(1-2):191-198
The extent of post-dispersal weed seed predation in upland wheat fields converted from paddy fields was quantified in Shizuoka Prefecture, central Japan. We investigated the temporal variability in seed predation of Italian ryegrass (Lolium multiflorum Lam.), a non-native winter annual weed in Japan, during summer after the seed shed in both the field interior areas and boundary strips, and estimated the total seed loss due to predation during the summer. Furthermore, the contribution of invertebrates and vertebrates to seed predation was estimated by using exclosures. The total seed loss due to predation during four months (from late June to late October) in the field interior areas and boundary strips was estimated to be 35–43% (the maximum proportion of seed predation per two weeks = 27%) and 42% (25%), respectively. The seed predators in the field interior areas were vertebrates (rodents or birds) and invertebrates (crickets and ground beetles). In contrast, seed predators in the boundary strips were mainly invertebrates (crickets and ground beetles). The results of this study suggest that predators make a substantial contribution in the depletion of post-dispersal seeds of Italian ryegrass in converted paddy fields. 相似文献
6.
苏州垃圾填埋生命周期清单分析 总被引:2,自引:0,他引:2
采用理论计算和实测相结合的方法,求得了苏州七子山垃圾填埋埋场的生命周期清单。实践证明,理论计算和实测相结合是清单分析的有效方法,对今后的同类研究具有参考意义。研究中获得的清单包括生活垃圾的收集和运输、垃圾填埋的物耗和能耗,以及每吨填埋垃圾所排放的大气和水污染物的量,并考察了填埋气用于发电后对清单的影响。这些结果可以为众多的产品生命周期评价提供数据支持。 相似文献
7.
8.
Summary. In this paper we report on the chemical basis for trail recognition in Lasius nipponensis. On and near trails in the field, workers became aggressive against conspecific intruders and succeeded in protective contests, while intruders usually avoided confrontation. Such asymmetric interactions were also observed in the laboratory when two non-nestmate workers were sequentially placed in a clean glass dish, while mutual aggression was observed when they were placed simultaneously. Asymmetric aggression was also observed when the workers were placed in a dish previously conditioned by other workers, or when the dish was treated with the hexane rinse of the conditioned dish. The rinse contained a series of hydrocarbons, in which components and proportion were almost identical to those of the cuticular hydrocarbons of the workers, except for a lack of n-alkanes. Amounts of the hydrocarbons that remained on the dish were very small when all the tarsi of the workers were incapacitated. We therefore consider that the hydrocarbons are not adhesion of the cuticular hydrocarbons but secretion from the tarsi of workers, and serve as a key signal for trail recognition in this ant. 相似文献
9.
Youssouf Boundou Sylla Masao Kuroda Masayuki Yamada Naoko Matsumoto 《Waste management & research》2006,24(5):456-464
Pilot-scale composting was carried out with cow manure to evaluate the performances of two passive aeration systems: a conventional passive aeration system equipped with horizontal pipes and an unusual passive aeration method based on air delivery by means of vertical pipes. The effects of both types of passive aeration apparatus were investigated in order to determine the degree of composting rate by continuously monitoring temperature, moisture content, organic matter, electrical conductivity, pH and C/N ratio in the piles. Temperatures in the range of thermophily (55-65 degrees C) were reached in all runs within 1-2 days then lasting for about 1 week, a span long enough for pathogen abatement. Results suggest that passive aeration carried out by vertical pipes is more effective for air delivery into compost piles than conventional passive aeration of air adduction with horizontal pipes. The variation in the number of vertical pipes was revealed to be an important parameter for the control of composting rate and temperature. Composting rates estimated from the heat balance equation were substantially in agreement with those computed through the conversion ratio of total organic matter decrement. The conversion ratios and composting rates obtained in this study using passive aeration with vertical pipes were well aligned with those found using forced air delivery systems. 相似文献
10.